All Gensets are available in 50Hz and in 60Hz Configuration !!

To view and print PDF File Spec Sheets you will need the Adobe Acrobat Reader software. You can download a copy of Adobe Acrobat Reader software free directly from Adobe Systems Incorporated.

getacro.gif (712 bytes)

 


ntg.jpg (1639 bytes)

redtri.gif (868 bytes)
12,000 kW / 12MW (15,000 kVA) - 50Hz

Skid-mounted
CATERPILLAR G3520C Natural Gas Power Plant consisting of six (6) Generator Sets reconditioned and overhauled by RING POWER, "0" HOURS SINCE RECONDITIONING.

Factory designed Gensets with robust block design that provides prolonged life and lower operating costs. V-20, 4-Stroke-Cycle Turbocharged-Aftercooled Natural Gas Engine. Manufactured according to ISO 9001.

Rating of each Genset in 50Hz Configuration:

2500 kVA (2000kW) CONTINUOUS POWER*
400V, 3 Phase, 50Hz @ 1500 rpm

*CONTINUOUS - Output available without varying load for an unlimited time, and 10% overload, in accordance with ISO8528, ISO3046/1, AS2789, DIN6271, and BS5514. All ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046/1, DIN6271, and BS5514 standard conditions. Ratings are based on pipeline natural gas having an LHV of 35.6 MJ/N•m³ (905 Btu/cu ft) and 80 MN. For values in excess of the altitude, temperature, inlet/exhaust restriction, or for natural gas compositions different from the conditions listed, other ratings may apply.

The G3520C is designed to parallel baseload to the utility grid.

Transformers can be utilized to step up, or to step down to any other Voltage. The power plant can also be modified to operate in 60Hz configuration (optional).

BASIC TECHNICAL DATA:

Engine Speed: 1500 RPM
Compression Ratio: 11.3:1
Fuel:  Natural Gas
Fuel System: Low Pressure  (0.50 – 5.0 PSIG)
Min. Methane Number:  80
Rated Altitude: 821 ft


BRIEF DESCRIPTION OF EQUIPMENT:

- CAT EMCP II+ Digital Generator Control Panel mounted on each Generator Housing
- Ammeter-Voltmeter Phase Selector and Voltage Adjust Potentiometer
- Automatic Start-Stop Function
- Safety Shutdowns and Alarm (Complete Safety System)
- Alarm Module – NFPA 110
- LCD Digital Readout for Engine and Generator Diagnostics
- CAT SR4B Two-Bearing, Six Lead, Three Phase, Platinum Stator RTD’s, Generator (Alternator) with 150% Overspeed Capability
- Class H Generator Insulation with Tropicalization and Antiabraison
- Digital Voltage Regulator
- Winding Temperature Detectors
- Space Heater
- Output Terminal, Bus Bar Termination Extension Box
- Electronic Air/Fuel Ratio Control (ECM), ADEM III based, with Electronic Fuel Control Valve, Throttle Plate, 24V DC Actuator, electronically controlled by ECM, Gas Shutoff Valve, 24V energized-to-run
- Electronic Governor
- Dual 50MT 24V Electric Starter
- Battery Disconnect Switch
- CAT G3520C Gas Engine
- Ignition System and Air/Fuel Ratio Control for lower Emissions and Engine Efficiency, individual Cylinder Timing and Detonation Control Sensors
- Thermocouples to input individual Exhaust Port Temperatures and Turbo Inlet and Outlet Temperatures on both the Turbine and Compressor
- Dry Exhaust Manifolds, insulated and shielded
- Center Section cooled Turbocharger
- Oil Pan Drain Valve
- Sump Pump
- Crankcase Breathers
- Gear Type Lube Oil Pump
- Integral Lube Oil Cooler
- Lube Oil and Filters
- 1st Stage Aftercooler Circuit for maximum Heat Recovery
- Separate Circuit 2nd Stage Aftercooler
- Dual Element Air Cleaners with Enclosure, Service Indicator, horizontal - Mount (shipped loose)
- Jacket Water Heater with Pump
- ANSI/DN Connection for JW Outlet and Cooling System Connection
- Open rail / skid-mounted, 330mm Structural Steel Rails
- Petroleum EPG Design compliant
- Durable Paint CAT Yellow)
+ many other standard Accessories (see Spec & Data Sheet)

   
    
 

S/N: CWW00101 0 HOURS SINCE RECONDITIONING
6175 Hours
Since NEW

Manufactured in
July 2003
Delivered / First Time commissioned in January 2004

RECONDITIONED
BY RING POWER CAT
IN 2007*

Unit is in “like new” Condition !

(*Work scheduled for October/November 2007)

S/N: CWW00114 0 HOURS SINCE RECONDITIONING
7313 Hours
Since NEW
S/N: CWW00115 0 HOURS SINCE RECONDITIONING
6350 Hours
Since NEW
S/N: CWW00120 0 HOURS SINCE RECONDITIONING
6705 Hours
Since NEW
S/N: CWW00122 0 HOURS SINCE RECONDITIONING
6208 Hours
Since NEW
S/N: CWW00129 0 HOURS SINCE RECONDITIONING
6371 Hours
Since NEW


12 MW Power Plant Package Price: US$ 383.00 Per kW

(These Units are also available as individual Gensets)

LOAD TESTED / PAINTED / COMPLETELY RECONDITIONED
WARRANTY:
6 Months RING POWER World Wide CAT Dealer Warranty

 




 


G3520C Genset

G3520C Power Plant

G35-Series Natural Gas
Power Plant

icon.specs.gif (104 bytes)

Spec Sheet 1

icon.specs.gif (104 bytes)

Spec Sheet 2

The Product Specification Sheet can be viewed or downloaded and printed on your printer.




































































































 


ntg.jpg (1639 bytes)

redtri.gif (868 bytes)
970 kW (1250 kVA) 50HZ @ 1500 RPM

Rebuilt Caterpillar G3516-SITA Natural Gas Package Generator Set. CAT SR4 generator, generator control panel,  auto start / stop, engine safety shutdowns, engine control panel, digital tachometer, circuit breaker, pyrometer group, thermoucouples, governor, dual 24V starters, 24 V/ 35 A charging alternator, standard duty air cleaners, jacket water heater, skid rail mounted, no radiator (optional available).

S/N: 3RC00678 0 Hours
Since REBUILT
Model 1993 US$ 250,000
REBUILT / LOAD TESTED / SERVICED / PAINTED
WARRANTY:
12 Months RING POWER World Wide CAT Dealer Warranty



























 

icon.specs.gif (104 bytes)

Spec Sheet

The Product Specification Sheet can be viewed or downloaded and printed on your printer.


ntg.jpg (1639 bytes)

redtri.gif (868 bytes)
125 kW (156 kVA) @ 60Hz
   
125 kVA @ 50Hz


Caterpillar / Olympian Model CG125 Natural Gas or LV Vapor Package Generator Set. HINO 13.3 ltr. gas engine, permanent magnet brushless generator with voltage regulator, Premium generator control panel, auto start-stop, safety shut downs, circuit breaker, Barber Coleman electronic governor, 24V starter, 35Amp alternator, jacket water heater, air cleaner, critical muffler, radiator, enclosure.

S/N: 2025458 452 Hours
Since NEW
Model 1996 US$ 15,500
LOAD TESTED / SERVICED
WARRANTY:
6 Months RING POWER World Wide CAT Dealer Warranty













 

icon.specs.gif (104 bytes)

Spec Sheet

The Product Specification Sheet can be viewed or downloaded and printed on your printer.



 




ntg.jpg (1639 bytes)

redtri.gif (868 bytes)
80 kW (100 kVA) @ 60Hz
   
80 kVA @ 50Hz

Caterpillar Olympian Model CG080
Natural Gas or LV vapor Package Generator Set.
7.4 ltr. gas engine, brushless generator with voltage regulator, Premium control panel, auto start-stop, safety shut downs, circuit breaker, governor, 12V starter, battery charger, jacket water heater, air cleaner, critical muffler, radiator, enclosure.
 

S/N: 2025460 547 Hours
Since NEW
Model 1996 US$ 10,500
LOAD TESTED / SERVICED
WARRANTY:
6 Months RING POWER World Wide CAT Dealer Warranty













 








 
icon.specs.gif (104 bytes)

N/A

The Product Specification Sheet can be viewed or downloaded and printed on your printer.


ADDITIONAL LARGER GAS GENSETS WITH BI-FUEL:

The following 60 Hertz / 50 Hertz generator sets we have listed are retrofitted to run on Bi-Fuel (DUAL-FUEL) "Natural Gas" and "Diesel" with the ability to operate on 100% diesel if the natural gas supply is interrupted. The dual fuel system reduces fuel expense, extend diesel fuel tank run-time, lower exhaust emissions, and prolong engine life and maintenance. Almost all the other 60 Hertz / 50 Hertz generator set’s you see in our "Diesel Section / Used Generator Set List" can also be converted to "Bi-Fuel / Dual-Fuel" operation.

Applications
: Prime Power, Peak Shaving, Co-Generation.

The below listed generator sets average from 100% diesel to 80%-50% natural gas and 20% to 50% diesel dual-fuel operation. Engines maintain "Full Rated Horsepower" at factory recommended operating temperatures.

Further below you will find a complete and detailed explanation of the BI-FUEL (DUAL-FUEL) technology.


dfu.jpg (1173 bytes)

redtri.gif (868 bytes)
2000 kW / 2500 kVA
           *** In Stock Ready to Ship ***

Caterpillar XQ2000 3516B- DITA BI-FUEL Diesel Power Module. 40’ container and chassis, Low Emissions and CARB certified, Sound Attenuated Utility Grade chassis, 1250 gallon fuel tank, auto fuel transfer system, premium digital control panel, auto start/stop, safety shutdowns, automatic paralleling, circuit breaker, batteries, charger, muffler, interior lighting and many other accessories. State-of-the-art equipment,.. Like Brand NEW.

Various Units low Hours Model 2000 CALL
AVAILABLE !!
WARRANTY:
1 Year Bi-Fuel System Warranty

6 Month Ring Power Worldwide CAT Dealer Warranty










xq2000.jpg (4942 bytes)

xq20001.jpg (6452 bytes)

icon.specs.gif (104 bytes)

Spec Sheet

The Product Specification Sheet can be viewed or downloaded and printed on your printer.

 


MORE SETS CAN BE CONVERTED TO BI-FUEL / DUAL-FUEL.
PLEASE CONTACT US FOR MORE INFORMATION !!



BI-FUEL (DUAL-FUEL) TECHNOLOGY:


Ring Power’s GTI® Bi-Fuel (Dual Fuel) system is based on a fumigation principle first observed by Mr. Rudolph Diesel, the inventor of the Diesel engine. Natural gas enters the engine with normal combustion air through the air filter, before the turbo charger. A significantly reduced amount of diesel fuel continues into the engine, which serves as a pilot ignition source for the natural gas. Our control system maintains the proper balance of natural gas, diesel and air to meet the engine’s BTU power requirements. Applications using controls for dual-fuel fumigation technologies are subject to U.S. patent, with foreign patents pending.

The Ring Power GTI® fumigation system does not add spark plugs or change other specifications within the engine, so factory warranties remain in effect. Engines maintain full rated horsepower/kw at factory recommended operating temperatures. Emissions such as NOx can be lowered by as much as 60%. Oil changes can be extended approximately 3 times normal. Black exhaust smoke (particulates) can become clear.

The Ring Power GTI® Bi-Fuel System operates by blending diesel fuel and natural gas in the combustion chamber. This is achieved using a pilot-ignition, fumigated gas-charge design, whereby natural gas is pre-mixed with engine intake-air and delivered to the combustion chamber via the air-intake valve. The air-gas mixture is ignited when the diesel injector sprays a reduced quantity of diesel fuel into the chamber. This diesel "pilot" acts as the ignition source for the primary air-gas combustible. Because of the high auto-ignition temperature of natural gas, the air-gas mixture will not ignite during the compression stroke, as there is not enough heat present to facilitate combustion.
 


MORE SETS CAN BE CONVERTED TO BI-FUEL / DUAL-FUEL.
PLEASE CONTACT US FOR MORE INFORMATION !!



df1.jpg (17260 bytes)

THE SYSTEM:

Because the OEM air-intake and diesel injection systems are utilized by the Bi-Fuel (Dual-Fuel) System, no engine modifications are required for installation.

The various components of the Bi-Fuel System are installed externally of the engine, and at no time is the engine disassembled during installation. All OEM engine specifications for injection timing, valve timing, compression ratio, etc., remain unchanged after installation of the Bi-Fuel System. The Bi-Fuel System requires a low pressure natural gas supply (approximately 2 - 5 psi) with a flow rate of approximately 8 scfh/kW (i.e. 500 kW=5,000 scfh).

INSTALLATION:

The Ring Power GTI® Bi-Fuel System is applied by trained technicians, with the installation normally taking anywhere from a few hours to a few days depending on the size of the generator. During nearly all of the installation process, the generator can be utilized for emergency power with little or no starting delay if the system is applied at the customers job site. Actual downtime of the generator is limited to only a few minutes, and rental back-up power is normally not required during installation of the System.


After installation of the Ring Power GTI® Bi-Fuel System hardware, the generator is then operated under various load settings (normally with the use of a resistive load bank) while the System is checked and calibrated. After this "tune-in" process is completed, the generator is fully tested in Bi-Fuel mode to assure proper operation of the Bi-Fuel System and generator during light, medium, heavy and transient loads. Finally, the generator is tested in 100% diesel mode to verify that its 100% diesel performance has not been effected by installation of the Bi-Fuel System.



df4.jpg (14326 bytes)

PERFORMANCE:

Installation of the Ring Power GTI® Bi-Fuel System in no way compromises the performance of the generator relative to the rated load of the machine. A generator with a 1000 kW stand-by rating which has been retrofitted to Ring Power GTI® Bi-Fuel System will still provide 1000 kW of power in both 100% diesel and Bi-Fuel modes. In other words, the generator is not de-rated after installation of the Bi-Fuel System. Similarly, there is no decrease in generator load response or stability while operating in either fuel mode.

SAFETY AND CONTROLS:

The Ring Power GTI® Bi-Fuel System incorporates a sophisticated, electronic control system, which controls both natural gas and diesel fuel during operation. In addition, the GTI Electronic Control System (ECS) acts as an engine safety device, by monitoring up to 24 critical data channels including:


Exhaust Gas Temperature-Stack

Exhaust Gas Temperature-Cylinder

High engine manifold air pressure (MAP)

Low natural gas supply pressure

High natural gas supply pressure

High engine vacuum





The various data channels are displayed on the ECS via an LCD display in either text or graphical format. The ECS notifies the user locally (via an LED general fault light) or remotely via modem, in the event of a fault.

If a fault is detected, the ECS will automatically switch the generator to 100% diesel operation and data-log the fault. The ECS fault set points are field adjustable and allow installation technicians to customize the Bi-Fuel System to the specific requirements of the customer and/or the operational limitations set-forth by the engine manufacturer. Once programmed, the fault settings are protected by a keypad lockout code, which prevents unauthorized personnel from altering the set points.


The ECS guarantees that in the unlikely event of either a Bi-Fuel System malfunction, or a disruption in natural gas supply pressure (either low or high pressure faults), the generator drive-engine will be protected from damage. Most of the monitored channels are latching type faults, i.e. if the Bi-Fuel System is deactivated by the ECS, the generator cannot be returned to Bi-Fuel operation until the ECS panel is manually reset. Lastly, the ECS also incorporates a built-in time delay function, which prevents initiation of Bi-Fuel operation after generator start-up, for a period of up to 300 seconds. This feature is used when the converted generator is used in paralleling operations, and allows the generator to start-up and synchronize on 100% diesel fuel before automatically switching to Bi-Fuel operation.


SAVINGS:

Savings derived from the use of Ring Power’s GTI® Bi-Fuel System are the result of either:


..the differential between the cost per kWh charged by the utility and the cost per kWh to produce power with a Bi-Fuel generator or,


..in the case of existing diesel prime power operations, the differential in the cost of diesel fuel and natural gas.



UTILITY SUPPLIED POWER:


Due to the premium prices which utility companies usually charge for on-peak electricity, it is often most viable to operate the Bi-Fuel generator as a peak-shaver, whereby power is produced on-site only during those hours when electricity is at it’s highest price from the utility. In order to determine the cost of producing power with a Bi-Fuel generator, several factors must be considered including:

Cost of natural gas


Cost of diesel fuel


Cost of maintenance program
for generator


Cost of future engine overhauls

df5.jpg (12442 bytes)

df6.jpg (12023 bytes)


SUMMARY OF
DUAL-FUEL BENEFITS:


>> Convert any Diesel Engine
>> Run Bi-Fuel or 100% Diesel
>> Generators, Ind. Engines, Marine
>> Lower Emissions – C.A.R.B.
>> Extend Oil Changes, Engine Life
>> Smaller Diesel Fuel Tanks Needed
>> Full Power, normal Temperatures
>> Costs much less than Gas Engines



More detailed Bi-Fuel (Dual-Fuel) Information and System Drawings   gosq.gif (266 bytes)


FREQUENT ASKED QUESTIONS:

What does "Bi-Fuel" mean?

In simple terms, Bi-Fuel can be defined as the simultaneous combustion of two fuels. In the case of Ring Power’s GTI® Bi-Fuel System, natural gas is utilized in conjunction with diesel fuel to operate the engine. After conversion, the engine is able to operate on either 100% diesel fuel, or alternately, on a mixture of diesel fuel and natural gas (or other methane based fuels). At no time is the engine able to operate on natural gas exclusively.

Will my engine have to be modified to operate on GTI Bi-Fuel?

No. Ring Power’s GTI® conversion technology has been designed to allow for in-field retrofit of diesel engines without the need to change or modify the design of the engine. Ring Power’s GTI® conversion hardware is mounted externally on the engine and does not require modification of the engine or alteration of any critical engine parameter.

What about my engine warranty?

Most OEM engine warranty programs do not prohibit the use of aftermarket parts or technologies. In brief, the policy of OEM's is that they neither recommend nor endorse aftermarket technologies, however, the use of these products does not automatically void the validity of the engine warranty. In practice, if a converted engine has a failure under warranty, the OEM, in conjunction with Ring Power’s GTI® technical personnel, make a determination as to the cause of the failure. If the cause is obviously unrelated to Bi-Fuel, the OEM's have historically honored the warranty and repaired the engine. If the cause is determined to be Bi-Fuel related, Ring Power’s GTI® team will cover repair costs under it's warranty program.

Why can't the engine use 100% natural gas?

Because of the very High ignition temperature of natural gas (approximately 1300T), sufficient heat is not generated during the diesel compression stroke to ignite 100% natural gas. As such, dedicated gas engines employ spark plugs and an ignition system to facilitate combustion of the air-natural gas mixture. In contrast, during Bi-Fuel operation, a reduced quantity of diesel fuel acts as the ignition source for the air-gas mixture; this process is often referred to as pilot ignition.

Will my engine lose power after conversion to Bi-Fuel?

Under normal circumstances, engines converted to Ring Power’s GTI® Bi-Fuel do not suffer any horsepower/kW losses while operating in Bi-Fuel Mode. Because the System maintains OEM compression ratio values and does not incorporate an air-throttling device, peak horsepower and efficiency levels of the converted engine remain on par with 100% diesel operation. In some circumstances, the engine may be de-rated in Bi-Fuel mode due to shortcomings in gas supply composition and/or quality.

Will my engine run hotter on Bi-Fuel?

Ring Power’s GTI® Bi-Fuel technology has been designed to maintain OEM specifications for all engine temperatures including engine coolant temperature, oil temperature, exhaust gas temperature and intake air temperature. The Bi-Fuel System replaces diesel fuel normally consumed by the engine with an equivalent quantity of natural gas, relative to the heat value of each fuel. As such, engine air-fuel ratios during Bi-Fuel operation remain largely equivalent to 100% diesel operation, resulting in normal peak exhaust gas temperatures and associated peak engine thermal loads.

What about efficiency?

As explained above, Ring Power’s GTI® Bi-Fuel System replaces diesel fuel with an equivalent quantity of natural gas. This process results in the same net fuel burn vs. load as would be experienced during 100% diesel operation. For each gallon of diesel fuel displaced during Bi-Fuel operation, there is a corresponding consumption of approximately 140 cubic feet of pipeline quality natural gas (based on 129,000 btu/gallon # 2 diesel & 930 btu/scf natural gas). Thus, for each gallon of diesel fuel displaced during Bi-Fuel operation, an "equivalent gallon7 of natural gas is consumed resulting in similar engine fuel efficiencies. Note: 1 d of natural gas = I liter # 2 diesel.

What effect will Ring Power’s GTI® System have on the durability of my engine?

Generally speaking, operation in Bi-Fuel mode has no negative effects on engine wear rates and durability. As explained above, because engine thermal loads are equivalent to 100% diesel operation, no excess wear of combustion chamber components (pistons, rings, valves, injectors, etc.) occurs. In addition, many users of Bi-Fuel have reported positive benefits relative to engine wear including extended oil change intervals and extended time between overhauls. This is primarily the result of the cleaner burning characteristics of natural gas compared to diesel fuel.

What are the economic benefits to operating on Bi-Fuel?

Fuel cost savings resulting from operation in Bi-Fuel mode win vary according to the respective cost of each of the fuels. If there is a significant cost differential between the cost of diesel fuel (per gallon, liter, etc.) and the equivalent quantity of natural gas (heat value basis) in favor of the natural gas, significant fuel cost savings would result. The closer the fuels are in price, the lower the fuel cost savings will be during Bi-Fuel mode. In addition to fuel cost savings, engine maintenance savings (as explained above) may also contribute to the economic benefit of Bi-Fuel operation.

More detailed Bi-Fuel (Dual-Fuel) Information and System Drawings   gosq.gif (266 bytes)

 
 